PVPROSSign in ↗
BECOME AN ENERGY EXPERT

Know where your
electricity goes.
And what it costs.

Monitoring built around your property and the questions you want answered.

From a heat pump at home to refrigeration in a restaurant, optional metering helps you understand where electricity goes, what it costs and how solar and batteries contribute.

Join free, complete your property profile, then find Energy Expert on your dashboard.
WHAT WOULD YOU LIKE TO UNDERSTAND?

Choose the insight.
We help plan the equipment.

You do not need to know which meter to buy. Start with what matters to you; your property details help shape a suitable monitoring plan.

01 · THE WHOLE PICTURE

Your whole property

Understand what you buy from the grid, what you export and how that contributes to your bill.

What gets installed
A suitable meter on the main supply, such as the ADW310, with a data connection.
What you see in PV Pros
Measured grid imports and exports, their value at your tariff rates, and an estimated running bill.

Independent readings can help highlight differences in billing or inverter data.

02 · FOUR LOADS, MORE INSIGHT

Your biggest electrical loads

Find out what individual equipment costs to run, rather than seeing only a whole-property total.

What gets installed
An ADW210 with sensors on four chosen loads, connected through an AWT100 gateway. Only your selected loads are monitored individually.
What you see in PV Pros
Consumption and estimated running cost for each named load, plus how solar and battery energy contribute where the required readings are available.

Choose and name your four loads. Add breaker details if known and photos to help plan installation.

03 · BUILT FOR YOUR SITE

Larger properties & multiple buildings

Understand energy use across your business, restaurant, farm or site, with a plan for each area.

What gets installed
A reviewed combination of main-supply meters, load-monitoring meters and gateways suited to your boards and supply.
What you see in PV Pros
Usage and cost insights for the areas and equipment you choose to monitor, alongside your whole-property picture.

Tell us about each board or building. The plan accounts for meter capacity and how readings reach PV Pros.

Mix the options to suit you.

You can combine whole-property and individual-load monitoring. PVPal can explain the choices as you build your plan.

Start with a free account

Illustrations explain the monitoring concept, not installation wiring. Costs and savings depend on reading coverage and your tariff. Load-level solar and battery contributions are calculated estimates, not separate measurements of where each unit of electricity came from.

BUILT AROUND YOU

Your property. Your priorities.

Homes & apartments

Understand heating, EV charging and other large electrical loads.

Businesses & hospitality

Explore refrigeration, kitchens, heating and equipment across your premises.

Farms & larger sites

Plan monitoring around pumps, machinery, multiple buildings and three-phase supplies.

The right meter and number of channels depend on your supply, circuits and site layout. Only selected circuits are measured individually.

FREE IS A GREAT START. GO FURTHER WHEN YOU WANT.

More detail, on your terms.

Your community access stays free. Energy Expert adds optional equipment and a closer view of your energy; it does not take away your free features.

What you getPV Pros FreeEnergy Expert
Community & your profileIncluded for everyoneStill included
Energy & financial insightsFrom supported inverter data and your tariffAdds independent meter readings where installed
Weather & PVPal guidanceWhere your location and data support itGuidance informed by the extra readings available
Main electricity supplyFrom supported connected data sourcesIndependent import and export measurement
Large electrical loadsWhole-property picture from available dataIndividual readings for the circuits you choose to monitor
Equipment & commissioningNo hardware purchase requiredTailored equipment and installation or delivery, priced separately

Results depend on supported connections, reading coverage and accurate tariffs. Metered comparisons can highlight differences; they do not replace your supplier’s bill or guarantee savings.

YOUR PATH TO ENERGY EXPERT

Start with a question.
Build the right picture.

No need to choose meter models yourself. Your answers and saved property details help shape the assessment, with PVPal available to explain the steps.

  1. 01

    Tell us what matters

    Choose what you want to understand and use your existing property profile.

  2. 02

    Choose your loads

    Name the equipment you want monitored. Add optional breaker details and photos of your board, meter cabinet and inverter.

  3. 03

    Understand your plan and price

    See suggested equipment and available cost estimates. Equipment, installation or delivery, and SIM options are considered separately; the final design and quote need review.

  4. 04

    Choose how it gets installed

    PV Pros installation and commissioning, or delivery to site for your own installer. Availability and scope are confirmed with your quote.

Meet the equipment · specifications & simple layout

For homes, businesses, hospitality, farms and larger sites. The supply and circuit layout determine the equipment, not the property name.

How independent monitoring connectsElectricity passes from the utility meter along the customer mains to all property branches. A main CT measures that cable. Circuit CTs measure selected circuits only. Dashed lines show optional data paths through a gateway or cellular meter to PV Pros. This is a conceptual layout, not a wiring diagram.Utility / ESB meterExisting supplier meterProperty distributionInclude all branchesSelected large-load circuitsCircuit CTs → ADW210 / AMC200Other circuitsNot individually monitoredMain CT(s)ADW310 / ADW300Cellular variant + SIMAWT100 + SIMShared if compatibleSupported inverterOptional RS485 pathMDA → PV ProsValidated property readings
Gold: electricity. Blue dashed: measurement or data connection. Concept only: exact CT placement, protection, power wiring and communications require an installer’s design. Built-in cellular circuit meters can change this layout. A supported inverter cloud API is an alternative data path.
ADW310

Your main electricity supply

An independent view of grid import and export for a suitable single-phase supply.

Technical details & checks
  • 220 V nominal; paired 20(100) A transformer input
  • Active energy accuracy class 1
  • 85–265 V AC auxiliary supply
  • RS485, Wi-Fi and cellular are different ordering options

Confirm the exact cellular variant, paired CT, supply rating and position before all property branches.

Manufacturer documentation ↗
ADW300

Three-phase and larger supplies

Measures a suitable mains supply using correctly selected external current transformers.

Technical details & checks
  • Standard variant: 3 × 1(6) A current input; this is the CT secondary, not the site load limit
  • Nominal 3 × 220/380 V or 3 × 380/660 V variants
  • Standard active energy accuracy class 0.5S
  • 85–265 V AC/DC supply; communication options vary

Confirm exact model, CT primary and secondary, voltage system and communications. ADW300W and mV/Rogowski options are not interchangeable.

Manufacturer documentation ↗
ADW210

Four individual loads. Clearer running costs.

The PV Pros ADW210 setup monitors the consumption of four individual loads you choose. Name each load to see its electricity use and estimated cost when readings and tariffs are available.

Technical details & checks
  • Manufacturer maximum: four three-phase or twelve single-phase circuits
  • RS485 Modbus RTU; external gateway for mobile data
  • Matched mA-output CTs and connector arrangement
  • 85–265 V AC/DC auxiliary supply

PV Pros currently budgets conservatively for four circuits per unit. Higher single-phase capacity requires verified channel mapping, CTs and MDA support.

Manufacturer documentation ↗
AMC200-8E3

More circuits across larger properties

An AC multi-circuit option for commercial, farm and other larger installations.

Technical details & checks
  • Manufacturer maximum: eight three-phase or twenty-four single-phase circuits
  • RS485 Modbus RTU; certain variants include 4G
  • 85–265 V AC/DC auxiliary supply
  • AMC200L has a display; exact suffix determines options

PV Pros budgets conservatively for eight circuits per unit. Confirm AC 8E3 variant, CT outputs, channel mapping and price. Other AMC200 families include DC products.

Manufacturer documentation ↗
AWT100

A connection for your readings

A gateway transports supported meter and inverter data. It does not measure electricity itself.

Technical details & checks
  • Cellular and other communication variants are available
  • RS485 connection to supported devices
  • Power arrangement depends on variant and coupling
  • MQTT support requires the appropriate model and configuration

One gateway may serve meters and an inverter only when protocol, register map, serial settings, addresses and cable route are compatible. Confirm power supply and MDA integration.

Manufacturer documentation ↗

Catalogue 2026-11-04.1. Published capability does not confirm compatibility with a particular inverter, CT or MDA configuration. Final model suffixes and prices are confirmed during review.

A LITTLE MORE KNOWLEDGE. A LOT MORE POSSIBILITY.

What would you like to understand?

Create your free profile first. Your dashboard will have an Energy Expert button whenever you want a closer look.

Create my free account ↗Back to PV ProsAssessments are available now. Final quotation approval and online ordering are not yet available.